Scarborough
A modern take on traditional weatherboard, Scarborough® Weatherboard is a stylish product with strong shadow lines that will enhance both traditional and contemporary residential designs.
Scarborough® Weatherboards have a ship lapped profile which can be installed with a drained cavity solution and is gun nailable for quick and easy installation. The pre-primed boards can be cut at different lengths to minimise waste. Scarborough® Weatherboard is low maintenance, especially compared to natural timber products.
Features
- Strong shadow lines enhance both traditional and contemporary residential designs
- Gun nailable for quick and easy installation
- Low maintenance
- Concealed fixing system and no ship-lap profile
- Can be installed with a drained cavity solution
- Pre-primed boards can be cut at different lengths to minimise waste
APPLICATIONS
Result | |
Applications | Façades & Cladding |
Type of Building Structure | Residential Housing Buildings within the scope of AS4055 |
Wet Areas | No |
PANEL – DIMENSIONAL & GEOMETRICAL CHARACTERISTICS
Dimensional/Geometrical Characteristic | Specification | Manufacturing Tolerance | Relevant Standard |
Panel Width | 175mm | +1 -0 mm | |
Panel Length | 4200mm | -0 -3 mm | |
Panel Thickness | 12mm | +0.5 -0 mm | |
Profile | Shiplap | ||
Perpendicularity/squareness of edges | 1mm/linear meter | ||
Weight (typical) | 19.4kg/m2 | ||
Layout Options | Horizontal | ||
Jointing | Ship Lapped |
PANEL – STRENGTH & MOISTURE RELATED PROPERTIES
Physical Property | Result | Relevant Standard |
Modulus of Rupture (Wet) | > 9 MPa | AS2908.2 |
Modulus of Elasticity (Wet) | 3-5 GPa | AS2908.2 |
Density (Oven Dry) | 1350 kg/m3 | AS2908.2 |
Water Vapor Diffusion | Not Required | Not Required |
Water Tightness (24hrs) | No water droplet | AS2908.2 |
Water Absorption (Saturated – 48hrs) | 30 wt% | ASTM C 1186 |
Moisture Content (EMC) | 7 wt% | ASTM C 1186 |
Moisture Movement | 0.062% | ASTM C 1186 |
PANEL – OTHER DURABILITY/WEATHER RESISTANCE INDICATORS
Test | Result | Relevant Standard |
Heat Rain | PASSED (25 Cycles) | AS2908.2 |
Freeze Thaw | PASSED (50 Cycles) | AS2908.2 |
Warm Water Resistance | PASSED (56 days) | AS2908.2 |
Soak Dry | PASSED (25 Cycles) | AS2908.2 |
PANEL – FINISH CHARACTERISTICS
Characteristic | Result | Relevant Standard |
Finish | Preprimed | |
Coating Type | Sealer Type: Clear Sealer On Face | |
Colour Bodied | No | |
Paint Type | ||
UV Resistance | N/A | N/A |
Formaldehyde Emission Rate | N/A | N/A |
VOC Emission Rate | N/A | N/A |
Spectral Reflectivity Values | Solar Reflectance % | Solar Absorption % | Basix Colour | Relevant Standard |
Scarborough™ Weatherboards | N/A |
PANEL – FIRE RESISTANCE, THERMAL & ACCOUSTIC PROPERTIES
Characteristic | Result | Relevant Standard |
FIRE RESISTANCE | ||
Combustibility | Suitable for use in applications where non-combustible materials are specified by the Deemed to Satisfy Provisions of the 2016 BCA Vol 1 Amendment 1 Clause C1.9 (2015 BCA Vol Clause C1.12) | |
Fire Hazard Properties | Group 1 Av Specific Extinction Area <250 | AS/NZ 3837 |
Classification | 1 | AS/NZ 3837 |
Surface Burning Characteristics | Ignitability =0, Flame Propagation =0, Heat Release =0, Smoke Release=1 | AS1530.3 |
THERMAL CONDUCTIVITY | ||
Thermal Conductivity (λ-Factor) | ≈ 0.2704 W/m.K | |
Thermal Expansion Co-efficient | 0.005-0.01mm/mK | N/A |
ACOUSTIC VALUE | ||
Sound reduction (depends on construction) | N/A | N/A |
SYSTEM SOLUTIONS
Characteristic | Result | Relevant Standard |
Within Scope of AS4055? | Yes | |
Wind Loading – Residential housing buildings within the scope of AS4055 | N1, N2, N3, N4, N5, C1, C2, C3 | |
Weatherproofing | Suitable for all building classes as set out in the BCA (ie 1&10, 2-9) | N/A |
Cyclonic Conditions | N/A | N/A |
Fire Resistance Limits (FRLs) | Up to 90/90/90 | Refer to Gyprock® The Red Book™ |
Bushfire Construction | BAL 29 (Construction for Bushfire Attack Level 29 for an external wall) | AS 3959-8 |
Acoustic | Acoustic solutions of up to RW/RW+CTR 50/42 are detailed | Refer to Gyprock® The Red Book™ |
Thermal | Thermal solutions of up to RT(sum)/RT(win) 3.4/3.8 are detailed | Refer to Gyprock® The Red Book™ |
FIXING
Characteristic | |
Maximum Span (Stud Spacing) | Up to 600mm |
DIRECT FIX | |
Nail to Timber Frame | Yes |
Screw to Timber Frame | No |
Screw to Steel Frame | Yes |
INDIRECT FIX | |
Timber Frame | Yes |
Steel Frame | No |
Masonry Frame | No |
EXPOSED FASTENERS | |
Screw | No |
Rivet | No |
Nail | No |
CONCEALED FASTENERS | |
Clip | No |
Countersunk Screw/Nail | No |
Adhesive, Split Batten, etc. | No |
Hidden by Overlapping Panel | Yes |
Flush Jointed (Taped) | No |
WARRANTY
25 Years
- Weatherboards Product Flyer – PDF | 7.9MB
- Scarborough Product Warranty – PDF | 102.7KB
- Weatherboard and Plank Design & Installation Guide – PDF | 15.9MB
-
Fibre Cement Safety Data Sheet – PDF | 712.4KB
-
Cemintel Product Portfolio – PDF | 16.0MB
-
Scarborough Weatherboard BIM files – ZIP | 865.3KB
-
Scarborough Weatherboard Design & Installation Guide – PDF | 3.8MB
-
Cavity Wall Cladding Systems Design & Installation Guide – PDF | 3.8MB
-
Fire Performance Guide – Fibre Cement Cladding – PDF | 3.3MB
Product Enquiry